Modified Release Tablet Transfer and Dissolution Fix

Western India · Generic Pharma Companies

Overview

Transfer of a modified release tablet that failed dissolution f2 similarity on the receiving equipment train, resolved by granulation change rather than coating change.

The challenge

On our roller compactor the transferred blend produced a dissolution profile that failed f2 similarity against the reference at the 2 and 4 hour points, despite identical formula and coating weight gain.

What we did

Investigation traced the difference to ribbon density and the resulting granule size distribution, not the film coat. Compaction force and roll gap were re-established against a target ribbon solid fraction, restoring granule distribution and f2 similarity of 68 before any coating parameter was touched.

Project data

Root causeRibbon solid fraction, not coating
f2 similarity41 (fail) → 68 (pass)
Batch size300 kg blend
Trial batches4 before PPQ
StabilityZone IVb long-term and accelerated in progress
Transfer duration16 weeks

Standards applied

Scope supplied

Related

All projects by Stancor Pharma · Request a proposal